Exhaust gas recirculation (EGR) is a powerful control used to
suppress NOx emissions in engines.
The ECM model 5230 EGR Analyser offers rapid and accurate
measurements of both EGR and Lambda (AFR). The compact design and
speed of response of the 5230 analyser makes it ideal for
applications in a dynamometer or in-vehicle.
The EGR 5230 determines %EGR by measuring the O2 and pressures
directly in the intake and exhaust of the engine under test. The
instrument is non-intrusive and displays measurements in less than
one second.
| 5230 |
Parameter Range |
Accuracy |
| EGR |
0 to 100% |
+/- 0.5% (absolute) |
| Pressure Range |
0 to 517 kPa |
+/- 5.2 kPa |
| Lambda Range |
0.4 to 25 |
+/- 0.005 (at Lambda =1) |
| AFR Range |
6 to 364 |
+/- 0.1 AFR (at 14.6 AFR) |
| %O2 Range |
0 to 25% |
+/- 0.2 (at 0 to 2% O2) |
Features
- Output to LED local display
- Response time of less than 150 ms
- Programmable Fuel Type (as defined by H:C. O:C, N:C Ratio)
- 6 x User Defined Analogue Outputs (0-5V DC)
- CAN Programmable Communication Protocol
| EGR 5230 |
Feature |
Specifications |
| Measurement Ranges |
%EGR |
0 to 100% |
| - |
Lambda |
0.4 to 25 |
| - |
AFR |
6 to 364 |
| - |
%O2 |
0 to 25% |
| - |
Pressure |
0 to 517 kPa (75 psia) |
| Accuracies |
%EGR |
+/- 0.5% (absolute) |
| - |
Lambda, AFR |
+/- 1.0% (of reading) |
| - |
%O2 |
+/- 0.2% (absolute) |
| - |
Pressure |
+/- 5.2 kPa (+/- 0.75 psia) |
| Response Times |
%EGR (programmable) |
Less than 1 second |
| - |
Lambda, AFR, %O2 |
Less than 150 ms |
| - |
Pressure |
Less than 150 ms |
| Outputs |
6 x Analogue Channels |
0 - 5 VDC |
| - |
2 x LCD |
User Configurable to show %EGR, AFR, Pressure etc |
| Input Power |
11 to 28 VDC |
AC/DC Mains Power Option |

Front Panel - 2 channels of Display

Rear - CAN & Analogue Connections
Download Specifications for EGR 5230: